Elcometer: Ultrasonic material thickness
Technical information from the manufacturer on choosing and using instruments.
Learn more
Ultrasonic coating & wall thickness measurement – Ultrasound enables one-sided thickness measurement on pipes, vessels or suitable non-metallic coatings.
Thickness is derived from echo travel time and sound velocity. Wall thickness and coating thickness require different instruments and evaluation methods.
Match probe, frequency, range and couplant to material, temperature and geometry; set the appropriate sound velocity.
Plan readings on representative surfaces and critical areas such as edges, transitions or curves where the method permits. Check instruments and references before the series; achievable uncertainty also depends on geometry.
Record substrate, film condition, method, location, unit and individual readings. Evaluate averages and local deviations under the agreed specification rather than selecting favourable readings.
Technical information from the manufacturer on choosing and using instruments.
Learn moreTechnical information from the manufacturer on choosing and using instruments.
Learn moreIncorrect sound velocity causes systematic error; not every gauge separates coating and substrate.
Perform the specified verification with appropriate standards. Keep orientation, contact or distance and conditions consistent.
Match probe, base instrument and required range. Consider foils, zero plates, couplant or application-specific references where the principle requires them.
Tell us substrate, coating type, target thickness, geometry and measurement stage. We can narrow down suitable instruments and reference materials.
Send enquiry