Runout inspection instruments – Runout fixtures inspect rotationally symmetrical workpieces for deviations during rotation.
The workpiece is mounted relative to a defined datum and rotated; an indicator records variation. Radial and axial runout require different directions.
Choose centres or other specified support, length, diameter and direction; define datum and clamping.
Clean faces and workpiece, account for burrs and thermal equilibration. Align instrument and part with the measuring direction. For precision measurement, the ISO 1 reference temperature of 20 °C is relevant; consider thermal effects where necessary.
Record drawing feature, target or tolerance, datum, instrument, calibration status, readings and conditions. Near a tolerance limit, follow the agreed decision rule taking uncertainty into account.
Technical information from the manufacturer on choosing and using instruments.
Learn moreTechnical information from the manufacturer on choosing and using instruments.
Learn moreRunout includes form and location relative to the datum axis; it is not roundness of a single section.
Check zero or reference position as instructed. Repeat measurements with suitable force and stable support without deforming the part.
Match contacts, fixtures, masters and interfaces. Check compatibility with the specific instrument series and features required.
Send drawing feature, range, tolerance, geometry and location of use. We can help select instruments, standards and accessories.