Product information

The Elcometer 130 quickly and accurately measures the level of soluble salts on surfaces, almost five times faster than comparable Bresle test methods.
It is the perfect replacement for the SCM400.

User-friendly
  • Large buttons, ideal for gloved hands
  • Easy-to-use menus in multiple languages
  • High-contrast, easy-to-read display
  • Factory calibrated for immediate use
Accurate
  • Conductivity measurement to ±1%
  • Can be used in accordance with national and international standards
  • Automatic temperature compensation ensures repeatable, accurate results
  • Calibration verification tiles
  • Trend and batch reading chart formats for on-screen, instant analysis
Reliable
  • Repeatable and reproducible measurements
  • 2-year gauge warranty
  • Supplied with fully traceable test certificates
  • Batch & individual readings are stored with date and time stamp
Rugged
  • Heavy-duty, impact-resistant, dust- and water-resistant design to IP64
  • Wipe-clean, sealed unit, ideal for harsh environments
  • Scratch- and solvent-resistant display
Efficient
  • Instant readings enable multiple tests to be carried out efficiently
  • Alphanumeric batch identification
  • Compatible with ElcoMaster® and the ElcoMaster® Mobile App
  • Calibration offset enables the use of non-pure water up to 2 µg/cm²
Powerful
  • Measurement range up to 50 µg/cm² (3000 ppm)
  • USB and Bluetooth® data output to iPhone* or Android™ devices
  • Stores up to 100,000 readings in 1,000 batches
  • Soluble salt and conductivity gauge in one instrument
Note Calibration verification tiles are available to check the accuracy of the gauge

How to use a salt contamination meter

  1. Fill the syringe with 1.6 ml of high-purity water.
    Note: Impure water (up to 2 µg/cm²) can be automatically compensated by the meter.
  2. Dispense the 1.6 ml onto a clean, unused sample paper, ensuring all of the water remains on the paper.
  3. Place the moistened paper onto the area to be tested and press firmly into contours and irregularities to remove trapped air.
    Tip: Start the timer on the gauge. While you wait for the sample time to elapse, you can prepare additional tests.
  4. After 2 minutes, remove the paper from the surface and place it on the gold-plated electrodes.
  5. Close the lid, ensuring the magnetic catch is fully engaged.
    The reading is displayed automatically and stored in memory along with paper size, temperature, date and time.
  6. For small-area tests, half- or quarter-size papers can be used. The paper size is automatically recognized by the Elcometer 130 and the reading is calculated automatically.

Product Features

Product Features ■ Standard □ Optional
Model S Model T
Repeatable & reproducible measurements
Easy-to-use menu structure; in over 30 languages
Rugged, impact resistant, waterproof and durable; dust resistant; conforms to IP64
Bright color display; with permanent backlight
Scratch & solvent resistant display; 2.4" (6 cm) TFT
2-year gauge warranty*
USB power; via PC
Accuracy certificate
Calibration verification mode (with optional certified calibration tiles)
Ambient light sensor; with adjustable automatic brightness
Torch mode
Magnetic & tripod mounting points
Gauge software updates; via ElcoMaster® software
Data output
USB; to computer
Bluetooth®; to computer, Android™ & iOSǂ devices
ElcoMaster® software & USB cable
On-screen statistics
Number of readings, η; Mean (average), x; Standard deviation σ; Highest reading, Hi; Lowest reading, Lo; Coefficient of variation, CV%; Number of readings above the upper limit
Reading memory
Number of readings 100,000
Number of batches 1,000
Units & range µg/cm²
ppm
µS/cm
mS/cm
% salt content
mg/m²
0-25 0-50
0-3000
0-6000
0-6m
0-0.3
0-500
Measurement mode
Surface cleanliness
Conductivity
Calibration offset mode
Automatic temperature compensation
Individual readings are stored with date and time.
Plastic carrying case
Alphanumeric batch names; user definable on the gauge
Fixed batch size mode; with batch linking
Delete last reading
Limits; user-definable audible and visual pass/fail warnings
Review, copy, delete & batch delete & calibration settings
Trend chart; last 20 readings
Batch review chart
Analogue bar graph

Product Accessories

Accessories – Elcometer 130 Salt Contamination Meter
T13023980 Calibration verification tiles, set of 3 T13024094 Box of 100 high-purity test papers
T13024091 2.5 ml / 0.08 fl oz syringe (x3) T13024092 Box of 20 disposable vinyl gloves
T99922341 Self-adhesive screen protector (10 pcs) T13024098 Plastic tweezers (x2)
T13024093 Box of 20 self-sealing polyethylene bags T13024087 Box of 72 sensor wipes
T99911344 Pure water – 250 ml bottle T99921325 USB cable

Standards

Can be used in accordance with:

SSPC Guide 15


More information
  • Product number: 1040111
  • Manufacturer: Elcometer

Further manufacturer information

Reviews