Sundström SR 500/SR 602: Powered Air Purifying Respirator for Intensive, Warm, and Long Work Shifts
The Sundström SR 500/SR 602 respiratory protection set combines a battery-powered fan unit with a comfortable hood. It is particularly suitable for work areas where classic filter masks quickly reach their limits: during long shifts, high physical exertion, heat, or dust-intensive activities.
Product Overview: What is included in the set?
The set consists of the SR 500 fan unit and the SR 602 hood. According to the manufacturer, the scope of delivery includes a standard battery, charger, belt, particle filter, filter adapter, pre-filter, pre-filter holder, flow meter, plug set, cleaning cloth, and user documentation.
| Component | Practical Benefit | Reference Value / Specification |
|---|---|---|
| SR 500 Fan Unit | Continuously supplies the hood with filtered air | Airflow approx. 175–240 l/min |
| SR 602 Hood | Protects respiratory tract, head, and shoulders | Material Microchem 4000, weight with hose approx. 530 g |
| Protection Class | High protection performance in the matching Sundström system | TH3, nominal protection factor 500 |
| Temperature Range | Suitable for typical industrial and workshop environments | Operation -10 to +55 °C, < 90 % RH |
Recommended Basic Settings as Guidelines
The following values are practice-oriented guidelines. The risk assessment, filter selection, operating instructions, and company specifications always remain decisive.
| Situation | Recommendation |
|---|---|
| Long wearing time | Check battery level before starting, keep a replacement battery ready, and perform airflow test |
| Dust exposure | Check P3 particle filter and pre-filter according to the deployment plan and replace in time |
| Warm environment | Ensure a comfortable fit of the hood; the airflow helps maintain a fog-free field of vision |
| High physical load | Only start with a passed function check and take warning signals seriously |
Pro Workflow: How to Start Your Assignment Correctly
- Check the hazardous substance, particle load, and duration of use.
- Select the appropriate filter combination according to the risk assessment.
- Charge the battery and check for visible damage to the fan, hose, and hood.
- Correctly mount filters, pre-filters, and adapters.
- Perform an airflow test using the flow meter.
- Put on the hood and adjust the headband and neck seal comfortably.
- During work, pay attention to warning signals, airflow, and wearing comfort.
Troubleshooting: 4 Typical Problems
1. Low Airflow Warning Signal
Check filter for saturation, check hose for kinks, and check battery level. Then repeat the airflow test.
2. Field of Vision Fogs Up or Air Feels Uncomfortable
Check hood fit, air ducting, and hose connection. The SR 602 features air ducting that supports comfort and a clear field of vision.
3. Short Battery Life
Fully charge the battery, consider the age of the battery, and plan for a replacement battery during long shifts.
4. Uneven or Restricted Airflow
Check filter mounting, adapter, pre-filter holder, and hose routing. Replace blocked or heavily soiled components.
Maintenance: 5 Points for Reliable Protection
- Perform a visual inspection of the fan, hood, hose, and connections before every use.
- Replace filters and pre-filters according to load, specifications, and warning indicators.
- Clean the hood and components with suitable cleaning wipes.
- Store the battery in a dry, clean place according to temperature specifications.
- Do not improvise repairs on damaged parts; use only matching original parts.
Buy Sundström SR 500/SR 602 directly from Beschicht.com
Ideal for professional users seeking a comfortable powered air-purifying respiratory system with a hood for long shifts.
Go to ProductFAQ
What kind of work is the SR 500/SR 602 set suitable for?
For dusty, warm, long, or physically intensive work where a powered respiratory system offers more comfort than simple filter masks.
What protection class does the combination offer?
The combination of SR 500 with SR 602 is specified as a TH3 system. The nominal protection factor is stated as 500.
How high is the airflow?
The SR 500 is specified with an airflow range of approximately 175 to 240 l/min. The system warns if the airflow is too low.
How long does the battery last?
As a guideline, the manufacturer specifies several hours of operating time depending on the battery and airflow. With an HD battery, up to 11 hours are specified at lower airflow.
What must be checked before starting work?
Hood fit, hose connections, filter condition, battery, and airflow. The system should only be used after a successful functional check.
Conclusion
The Sundström SR 500/SR 602 set is a powerful solution for users seeking respiratory protection with high wearing comfort, continuous airflow, and practical system compatibility. Especially for long, warm, or dust-intensive assignments, the combination of fan, hood, and matching filters offers clear added value.