Colour measurement

Precise color measurement for perfect coatings. Reliably capture color tone and deviations for reproducible, consistent, and standard-compliant quality.
Request consultation

Color Measurement

Color measurement enables the objective evaluation of coating, plastic, printing and automotive surfaces. Spectrophotometers with d/8 or 45/0 geometry (optionally with SCI/SCE mode) are used, complemented by colorimeters and light booths with standardized illuminants. Recorded and evaluated are ΔE*ab and ΔE00, tolerance checks, color formulations as well as GLP-compliant reports – compliant with ISO 7724, ISO 11664, ASTM D2244 and ASTM E308.

Applications & Benefits

Color measurement technology is central for coaters, automotive/OEM applications, plastic and film manufacturers, printing and packaging companies as well as laboratory and QA departments. Precise color measurement systems ensure color consistency across batches, minimize rework and complaints and ensure audit-proof approvals – from incoming goods inspection to series production.

Measurement Tasks & Set Configuration

Instrument selection: d/8 geometry (with SCI/SCE) is used for precise color capture including gloss compensation, while 45/0 corresponds to the visual perception of the human eye. The measurement aperture and sample positioning are adapted to the material and texture.

Light booths: Standardized lighting conditions with D65, A and TL84 enable the visual evaluation of color fastness and metamerism. Switchable illuminants allow practical comparisons.

Tolerance checking & evaluation: Color deviations are displayed as ΔE*ab or ΔE00, optionally in Lab or LCh coordinates. Results are graphically represented and checked against predefined tolerance limits.

Documentation: Measurement data can be tracked via labels/QR codes, exported as PDF/CSV reports and archived in a tamper-proof way via serial number and user management. An integrated limit check supports fast approval processes.

Product Areas & Integration

The portfolio includes portable and benchtop spectrophotometers, colorimeters, light booths, calibration standards (white/black references), sample holders and color standards. In addition, QC and formulation software, app/cloud solutions and interfaces are available to process color data digitally. We define scope of testing, reference to standards and measurement point plans and integrate the systems into QA workflows, report archives and audit processes. Result: precise, reproducible color control with documented compliance with standards.

Advantages at a Glance

  • Standards-compliant – ISO 7724/11664 & ASTM D2244/E308
  • Process-safe – defined geometry, illuminants & tolerances
  • Digital documentation – labels/QR, statistics, PDF/CSV & traceability
  • Visually consistent – light booths for metamerism checks

Top Manufacturers – Color Measurement

  • X-Rite – spectrophotometers, light booths & software.
  • DeFelsko – Instruments for color measurement and quality control.
  • Konica Minolta Sensing – benchtop/portable spectrophotometers & colorimeters.
  • BYK-Gardner – spectro/gloss combination instruments & QC software.
  • Datacolor – formulation & quality control.
  • Rhopoint – appearance & visual assessment.
  • Techkon – color measurement instruments for printing/packaging.
  • Neurtek – color charts/standards & accessories.
  • PCE Instruments – color measurement instruments & loggers.
  • Testo – climate/ΔT for stable test conditions.
  • Rotronic – climate/humidity monitoring.
  • Extech – field/electrical measuring instruments.
  • OMEGA – sensors, probes & data acquisition.
  • Phoenix Instrument – laboratory/test equipment.
  • Grant – temperature/data loggers.
  • KSJ – portable inspection devices.
  • 3M – sample accessories & labels.
  • SIS Verlag – standards/guides & training.
  • Elcometer – mechanical test instruments & reporting.
  • SATA – accessories for compressed air.
  • beschicht. – QA templates, QR/label sets & customer-specific kits.

Go directly to Color Measurement – or Consulting & Instrument Configuration.

Guides & Resources

Better Coating: Beschichtpunkt Expands Sales Activities

How structured consulting and suitable measurement technology increase process reliability in coating.

Learn more

Surface Cleanliness: A Decisive Factor for Coating Quality

Why color consistency, gloss and cleanliness work together – for stable approvals and less rework.

Learn more

Frequently Asked Questions on Color Measurement

Which methods and standards apply to color measurement?

Common are spectrophotometers and colorimeters with geometries d/8 or 45/0 and optionally SCI/SCE. Relevant standards include ISO 7724 and ISO 11664 (CIE color space) as well as ASTM D2244 (color differences) and ASTM E308 (colorimetric calculation).

How do I select the right instrument, geometry and tolerances?

The selection depends on material/gloss level, texture and application. 45/0 is suitable for visual matching, d/8 allows SCI/SCE to control the influence of gloss. Illuminant and observer (e.g. D65/10°), measurement aperture, sample positioning as well as tolerances such as ΔE*ab or ΔE00 must be defined according to customer requirements.

How do I ensure accuracy and audit-proof documentation?

Through regular white/black references, conditioned samples, defined measurement geometry, multiple repeat measurements and GLP-compliant protocols. Documented are instrument/serial number, geometry/SCI-SCE, illuminant/observer, reference/sample, ΔE results and PDF/CSV reports with date/user/labels.

Customer Feedback

Request Color Measurement Now

We configure spectrophotometers, colorimeters and light booths including calibration standards, measurement point plans and documentation – compliant with ISO 7724/11664 and ASTM D2244/E308. Result: audit-proof evidence, stable approvals and minimal rework.

Request now