G3™ Pro grease lubricant pump, 90-240 VAC, 4 litres, DIN
€1,669.57*
Ready for shipping in 5-8 days
Longer service life, lower operating costs and higher productivity with the G3 from Graco! The G3 Pro has a flexible design and works with progressive and single-line systems. A cost-effective pump for a wide range of markets and applications. It comes standard with one adjustable pump element and room for two more. Ultimate flexibility - High quality and customised for your application.
- Built-in controller for setting the pump run and pause times
- Low level indicator with advance warning and switch-off.
- Push button for manual operation of the pump (remote control option available).
- Password-protected settings
- Pre-lubrication function for carrying out an initial lubrication cycle when the machine is started.
Alarm relay, maximum inductive operating voltage (VAC): | 250 |
---|---|
Alarm relay, maximum ohmic operating voltage (VAC): | 250 |
Application: | On-road vehicles, off-road vehicles |
Compatible dosing system: | Progressive system |
Compatible material: | Fat |
Contact power low level (W): | 10 |
Control options: | Per |
Current load (A), low level: | 1.2 |
Energy type: | Electric |
For use with: | Single-line systems, progressive systems |
Gender of the material outlet thread: | Internal thread |
IP dimensioning: | IP69K |
Includes: | Wiper arm |
Inductive maximum operating current, alarm relay (A): | 1.5 |
Inductive maximum permissible load, alarm relay: | 10 ?A;10m VDC |
Inductive maximum rated load, alarm relay (A): | 0.2 |
Inductive maximum switching capacity, alarm relay: | 25VA;30W |
Input, maximum switch-off current (mA): | 1.5 |
Input, response time (ms): | 60 |
Input cycle rate (Hz): | 8 |
Input impedance: | 1.1 |
Input load current (mA at 24 VDC): | 22 |
Low level switching capacity (VDC): | 200 |
Material outlet size (mm): | 6,3500 |
Material outlet thread type: | NPSF |
Maximum NLGI grade: | No. 2 |
Maximum filling inlet pressure (bar): | 344.7 |
Maximum filling inlet pressure (kPa): | 34470 |
Maximum filling inlet pressure (psi): | 5000 |
Maximum operating pressure (MPa): | 35.1 |
Maximum operating pressure (kPa): | 35160 |
Maximum operating pressure (psi): | 5100 |
Maximum rated residual voltage (V): | 4 |
Maximum running time (min): | 30 |
Maximum voltage (V ac): | 264 |
Minimum voltage (V ac): | 88 |
Model: | G3 |
Number of machine cycle counting sensor inputs: | 1 |
Number of pressure and cycle sensor inputs: | 3 |
Number of pump elements: | Up to 3 |
Permissible operating pressure (bar): | 351.6 |
Power connection type: | DIN |
Relief valve, output voltage (VDC): | 24 |
Relief valve maximum operating current (A): | 2 |
Relief valve maximum operating power (W): | 48 |
Required input switch type: | Normally open |
Reservoir size (L): | 4 |
Resistive maximum operating current, alarm relay (A): | 3 |
Resistive maximum rated load, alarm relay (A): | 0.4 |
Resistive maximum switching capacity, alarm relay: | 50VA;60W |
Sensor input voltage (VDC): | 24 |
Series: | Per |
Size of the material outlet opening (inches): | 0.25 |
Switching current (A), low level: | 0.5 |
Total depth (cm): | 25.4 |
Total depth (mm): | 254 |
Total height (cm): | 36.8 |
Total height (mm): | 368 |
Total width (cm): | 23.5 |
Total width (mm): | 235 |
Type: | Electric piston pump |
Voltage (V): | 90-240VAC |
Voltage (V ac): | 90-240 |
Weight (kg): | 6 |
Wetted material: | Nylon, Trogamid T5004-060, Galvanized Steel, Mild Steel, Alloy Steel, Stainless Steel, Nitrile Rubber, Bronze, Nickel Plated Alnico, Chemically Lubricated Acetal, Aluminum, PTFE, Grillamid |
- Product number: 1031322
- Manufacturer: Graco
- EAN: 00633955595248
- Weight: 7.701 kg
- Length: 390 mm
- Width: 310 mm
- Height: 270 mm
Technical details
Operating specifications
UPC product | 6 3 3955595248 |
---|---|
Division | LED |
Price Block | 128 |
Country of Origin | US |
Unit | EA |
Height | 27 CM |
Length | 39 cm |
Width | 31 cm |
Volume | . 033 m³ |
Shipping weight | 7 .7 KG |
Technical
Fluid outlet size (mm) | 6. 3500 |
---|---|
Fluid outlet thread gender | Female |
For use with | Injector-based systems, series progressive systems |
Includes | Wiper Arm |
Maximum NLGI Grade | #2 |
Maximum working pressure (bar) | 351. 6 |
Maximum working pressure (kPa) | 3 5160 |
Maximum working pressure (psi) | 5 1 00 |
Model | G3 |
Reservoir Size (gal) | 1. 06 |
Series | Pro |
Alarm relay inductive maximum operating current (A) | 1. 5 |
Alarm relay inductive maximum operating voltage (VAC) | 2 50 |
Alarm relay inductive maximum switching capacity | 25 VA; 30 W |
Alarm relay inductive minimum permissible load | 10 ?A;10m VDC |
Alarm relay inductive rated load (A) | 0. 2 |
Alarm relay resistive maximum operating current (A) | 3 |
Alarm relay resistive maximum operating voltage (VAC) | 2 50 |
Alarm relay resistive maximum switching capacity | 50 VA; 60 W |
Alarm relay resistive rated load (A) | 0. 4 |
Control Options | Per |
Input Cycle Rate (Hz) | 8 |
Input Impedance | 1. 1 |
Input load current (mA @ 24 VDC) | 2 2 |
Input Maximum Off Current (mA) | 1. 5 |
Input Maximum Residual Voltage (V) | 4 |
Input required switch type | Normally Open |
Input Response Time (ms) | 60 |
Input sensor voltage (VDC) | 2 4 |
IP Rating | IP 6 9K |
Low Level Carry Current (A) | 1. 2 |
Low Level Contact Rating (W) | 10 |
Low Level Switch Rating (VDC) | 2 00 |
Low level switching current (A) | 0. 5 |
Maximum fill inlet pressure (bar) | 344. 7 |
Maximum fill inlet pressure (kPa) | 3 4 470 |
Maximum fill inlet pressure (psi) | 5 0 00 |
Maximum run time (min) | 30 |
Maximum voltage (V ac) | 264 |
Minimum voltage (V ac) | 88 |
Number of machine count sensor inputs | 1 |
Number of pressure and cycle sensor inputs | 3 |
Number of pump elements | Up to 3 |
Overall depth (cm) | 25. 4 |
Overall depth (in) | 10 |
Overall depth (mm) | 2 54 |
Overall height (cm) | 36. 8 |
Overall height (in) | 14. 5 |
Overall height (mm) | 368 |
Overall width (cm) | 23. 5 |
Overall width (in) | 9. 25 |
Overall width (mm) | 2 35 |
Pump Output with 0 Spacers (cu in/min) | 0. 25 |
Pump output with 1 spacer (cu in/min) | 0. 18 |
Pump output with 2 spacers (cu in/min) | 0. 12 |
Vent valve maximum operating current (A) | 2 |
Vent valve maximum operating power (W) | 48 |
Vent valve output voltage (VDC) | 2 4 |
Weight (kg) | 6 |
Maximum working pressure (MPa) | 35. 1 |
Further manufacturer information
- 332301K, Handbuch, Automatische Schmiermittelpumpe G3 Pro, Einbau, Einrichten, Wartung, Teile (Deutsch)
- 332301K, Handbuch, Automatische Schmiermittelpumpe G3 Pro, Einbau, Einrichten, Wartung, Teile (中文)
- 332301K, Handbuch, Automatische Schmiermittelpumpe G3 Pro, Einbau, Einrichten, Wartung, Teile (日本語)
- 332301K, Handbuch, Automatische Schmiermittelpumpe G3 Pro, Einbau, Einrichten, Wartung, Teile (Español)
- 332301K, Handbuch, Automatische Schmiermittelpumpe G3 Pro, Einbau, Einrichten, Wartung, Teile (Français)
- 332301K, Handbuch, Automatische Schmiermittelpumpe G3 Pro, Einbau, Einrichten, Wartung, Teile (Italiano)
- 332301K, Handbuch, Automatische Schmiermittelpumpe G3 Pro, Einbau, Einrichten, Wartung, Teile (Polski)
- 332301K, Handbuch, Automatische Schmiermittelpumpe G3 Pro, Einbau, Einrichten, Wartung, Teile (русский)
- 332301K, Handbuch, Automatische Schmiermittelpumpe G3 Pro, Einbau, Einrichten, Wartung, Teile (English)
- 340574DE G3 elektrische Schmierstoffpumpe (Deutsch)
- 340574DE G3 elektrische Schmierstoffpumpe (English (UK))
- 340574DE G3 elektrische Schmierstoffpumpe (Français)
- 340574DE G3 elektrische Schmierstoffpumpe (русский)
- 340574DE G3 elektrische Schmierstoffpumpe (Español)
- 340574DE G3 elektrische Schmierstoffpumpe (Nederlands)
- 340574DE G3 elektrische Schmierstoffpumpe (Svenska)
- 340574DE G3 elektrische Schmierstoffpumpe (Italiano)
- 340574DE G3 elektrische Schmierstoffpumpe (Polski)
- 340706DE G3 Selection guide (Deutsch)
- 340706DE G3 Selection guide (English (UK))
- 340706DE G3 Selection guide (Français)
- 340706DE G3 Selection guide (русский)
- 340706DE G3 Selection guide (Español)
- 340706DE G3 Selection guide (Nederlands)
- 340706DE G3 Selection guide (Svenska)
- 340706DE G3 Selection guide (Italiano)
- 340706DE G3 Selection guide (Polski)
Register