G3™ Max. Grease pump, 24 VDC, 2L, follower plate, low level with monitoring, USB, DIN, 2 sensors, machine cycle counting, relief valve, alarm, remote operation
€2,967.86*
Ready for shipping in 5-8 days
Longer service life, lower operating costs and higher productivity with the G3 from Graco! Thanks to its flexible design, the G3 Max works with progressive and single-line systems. A cost-effective pump for a wide range of markets and applications. It comes standard with one adjustable pump element and room for two more. Ultimate flexibility - High quality and customised for your application.
- Built-in controller for setting the pump run and pause times
- Low level indicator with advance warning and switch-off.
- Push button for manual operation of the pump (remote control option available).
- Password-protected settings
- Pre-lubrication function for carrying out an initial lubrication cycle when the machine is started.
- Up to three inputs for pressure and cycle switches ensure correct lubrication cycles.
- Mix/match cycle and pressure switch for customised installations and feedback.
- Machine cycle count input - ideal for devices that are not used regularly.
- Fault indication to external alarm indicators.
Optional Data Management System (DMS)
- Work faster and smarter with Graco's exclusive Data Management System (DMS)
- Find out exactly how your lubrication system is working and how well lubricated it is
- Track history, ensure data protection, upload or download data with a simple USB flash drive.
Alarm relay, maximum inductive operating voltage (VDC): | 220 |
---|---|
Alarm relay, maximum ohmic operating voltage (VDC): | 220 |
Application: | On-road vehicles, off-road vehicles |
Compatible dosing system: | Progressive system, multi-line system |
Compatible material: | Fat |
Contact power low level (W): | 10 |
Control options: | Max |
Current load (A), low level: | 1.2 |
Energy type: | Electric |
For use with: | Single-line systems, progressive systems |
Gender of the material outlet thread: | Internal thread |
IP dimensioning: | IP69K |
Includes: | Machine counting, relief valve, DIN alarm output, M12 connection for remote control, follower plate, low level |
Inductive maximum operating current, alarm relay (A): | 1.5 |
Inductive maximum permissible load, alarm relay: | 10 ?A;10m VDC |
Inductive maximum rated load, alarm relay (A): | 1 |
Inductive maximum switching capacity, alarm relay: | 25VA;30W |
Input, maximum switch-off current (mA): | 1.5 |
Input, response time (ms): | 60 |
Input cycle rate (Hz): | 8 |
Input impedance: | 1.1 |
Input load current (mA at 24 VDC): | 22 |
Low level switching capacity (VDC): | 200 |
Material outlet size (cm): | 6,350 |
Material outlet size (mm): | 6,3500 |
Material outlet thread type: | NPSF |
Maximum NLGI grade: | No. 2 |
Maximum filling inlet pressure (bar): | 344.7 |
Maximum filling inlet pressure (kPa): | 34470 |
Maximum filling inlet pressure (psi): | 5000 |
Maximum operating pressure (MPa): | 35.1 |
Maximum operating pressure (kPa): | 35160 |
Maximum operating pressure (psi): | 5100 |
Maximum running time (min): | 30 |
Maximum voltage (V dc): | 32 |
Minimum voltage (V dc): | 18 |
Model: | G3 |
Number of machine cycle counting sensor inputs: | 1 |
Number of pressure and cycle sensor inputs: | 3 |
Number of pump elements: | Up to 3 |
Number of sensor inputs: | 3, 1 |
Permissible operating pressure (bar): | 351.6 |
Power connection type: | DIN |
Relief valve, output voltage (VDC): | 24 |
Relief valve maximum operating current (A): | 2 |
Relief valve maximum operating power (W): | 48 |
Required input switch type: | Normally open |
Reservoir size (L): | 2 |
Resistive maximum operating current, alarm relay (A): | 3 |
Resistive maximum rated load, alarm relay (A): | 2 |
Resistive maximum switching capacity, alarm relay: | 50VA;60W |
Sensor input voltage (VDC): | 24 |
Series: | Max |
Size of the material outlet opening (inches): | 0.25 |
Switching current (A), low level: | 0.5 |
Total depth (cm): | 9/22 |
Total depth (mm): | 229 |
Total height (cm): | 33.7 |
Total height (mm): | 337 |
Total width (cm): | 20.3 |
Total width (mm): | 203 |
Type: | Electric piston pump |
Voltage (V): | 24VDC |
Voltage (V dc): | 24 |
Weight (kg): | 6 |
Wetted material: | Nylon, Trogamid T5004-060, Galvanized Steel, Mild Steel, Alloy Steel, Stainless Steel, Nitrile Rubber, Bronze, Nickel Plated Alnico, Chemically Lubricated Acetal, Aluminum, PTFE, Grillamid |
- Product number: 1031775
- Manufacturer: Graco
- EAN: 00633955595026
- Weight: 7.257 kg
Technical details
Operating specifications
UPC product | 6 3 3955595026 |
---|---|
Division | LED |
Price Block | 128 |
Country of origin | US |
Unit | EA |
Height | 0 CM |
Length | 0 CM |
Width | 0 CM |
Volume | 0 M3 |
Shipping weight | 7 .26 KG |
Technical
Fluid outlet size (mm) | 6. 3500 |
---|---|
Fluid outlet thread gender | Female |
For use with | Injector-based systems, series progressive systems |
Includes | Machine Count, Vent Valve, DIN Alarm Output, M12 Connection for Remote, Follower Plate, Low Level |
Maximum NLGI grade | #2 |
Maximum working pressure (bar) | 351. 6 |
Maximum working pressure (kPa) | 3 5160 |
Maximum working pressure (psi) | 5 1 00 |
Model | G3 |
Reservoir Size (gal) | 0. 528 |
Series | Max |
Voltage (V DC) | 2 4 |
Alarm relay inductive maximum operating current (A) | 1. 5 |
Alarm relay inductive maximum operating voltage (VDC) | 220 |
Alarm relay inductive maximum switching capacity | 25 VA; 30 W |
Alarm relay inductive minimum permissible load | 10 ?A;10m VDC |
Alarm relay inductive rated load (A) | 1 |
Alarm relay resistive maximum operating current (A) | 3 |
Alarm relay resistive maximum switching capacity | 50 VA; 60 W |
Alarm relay resistive rated load (A) | 2 |
Control Options | Max |
Input Cycle Rate (Hz) | 8 |
Input Impedance | 1. 1 |
Input load current (mA @ 24 VDC) | 2 2 |
Input Maximum Off Current (mA) | 1. 5 |
Input Required Switch Type | Normally Open |
Input Response Time (ms) | 60 |
Input Sensor Voltage (VDC) | 2 4 |
IP Rating | IP69K |
Low Level Carry Current (A) | 1. 2 |
Low Level Contact Rating (W) | 10 |
Low Level Switch Rating (VDC) | 2 00 |
Low level switching current (A) | 0. 5 |
Maximum fill inlet pressure (bar) | 344. 7 |
Maximum fill inlet pressure (kPa) | 3 4 470 |
Maximum fill inlet pressure (psi) | 5 0 00 |
Maximum run time (min) | 30 |
Maximum voltage (V DC) | 32 |
Minimum voltage (V DC) | 18 |
Number of machine count sensor inputs | 1 |
Number of pressure and cycle sensor inputs | 3 |
Number of pump elements | Up to 3 |
Number of sensor inputs | 3, 1 |
Overall depth (cm) | 22. 9 |
Overall depth (in) | 9 |
Overall Depth (mm) | 229 |
Overall height (cm) | 33. 7 |
Overall height (in) | 13. 25 |
Overall height (mm) | 337 |
Overall Width (cm) | 20. 3 |
Overall width (in) | 8 |
Overall width (mm) | 2 03 |
Pump Output with 0 Spacers (cu in/min) | 0. 25 |
Pump output with 1 spacer (cu in/min) | 0. 18 |
Pump output with 2 spacers (cu in/min) | 0. 12 |
Vent valve maximum operating current (A) | 2 |
Vent valve maximum operating power (W) | 48 |
Vent valve output voltage (VDC) | 2 4 |
Weight (kg) | 6 |
Maximum working pressure (MPa) | 35. 1 |
cellular connectivity | No |