G3™ Max grease pump, 24 VDC, 2L, follower plate, low level with monitoring, 3 sensors, DIN, machine cycle counting, relief valve, alarm, remote operation
€2,596.58*
Ready for shipping in 5-8 days
Longer service life, lower operating costs and higher productivity with the G3 from Graco! Thanks to its flexible design, the G3 Max works with progressive and single-line systems. A cost-effective pump for a wide range of markets and applications. It comes standard with one adjustable pump element and room for two more. Ultimate flexibility - High quality and customised for your application.
- Built-in controller for setting the pump run and pause times
- Low level indicator with advance warning and switch-off.
- Push button for manual operation of the pump (remote control option available).
- Password-protected settings
- Pre-lubrication function for carrying out an initial lubrication cycle when the machine is started.
- Up to three inputs for pressure and cycle switches ensure correct lubrication cycles.
- Mix/match cycle and pressure switch for customised installations and feedback.
- Machine cycle count input - ideal for devices that are not used regularly.
- Fault indication to external alarm indicators.
- Optional Data Management System (DMS) - Work faster and smarter with Graco's exclusive Data Management System (DMS). Find out exactly how your lubrication system is performing and how well lubricated it is. Track history and ensure data protection, upload or download data with a simple USB flash drive.
Alarm relay, maximum inductive operating voltage (VDC): | 220 |
---|---|
Alarm relay, maximum ohmic operating voltage (VDC): | 220 |
Application: | On-road vehicles, off-road vehicles |
Compatible dosing system: | Progressive system, multi-line system |
Compatible material: | Fat |
Contact power low level (W): | 10 |
Control options: | Max |
Current load (A), low level: | 1.2 |
Energy type: | Electric |
For use with: | Single-line systems, progressive systems |
Gender of the material outlet thread: | Internal thread |
IP dimensioning: | IP69K |
Includes: | Machine counting, relief valve, DIN alarm output, M12 connection for remote control, follower plate, low level |
Inductive maximum permissible load, alarm relay: | 10 ?A;10m VDC |
Inductive maximum rated load, alarm relay (A): | 1 |
Inductive maximum switching capacity, alarm relay: | 25VA;30W |
Input, maximum switch-off current (mA): | 1.5 |
Input cycle rate (Hz): | 8 |
Input impedance: | 1.1 |
Input load current (mA at 24 VDC): | 22 |
Low level switching capacity (VDC): | 200 |
Material outlet size (cm): | 6,350 |
Material outlet size (mm): | 6,3500 |
Material outlet thread type: | NPSF |
Maximum NLGI grade: | No. 2 |
Maximum filling inlet pressure (bar): | 344.7 |
Maximum filling inlet pressure (kPa): | 34470 |
Maximum filling inlet pressure (psi): | 5000 |
Maximum operating pressure (MPa): | 35.1 |
Maximum operating pressure (kPa): | 35160 |
Maximum operating pressure (psi): | 5100 |
Maximum rated residual voltage (V): | 4 |
Maximum running time (min): | 30 |
Maximum voltage (V dc): | 32 |
Minimum voltage (V dc): | 18 |
Model: | G3 |
Number of machine cycle counting sensor inputs: | 1 |
Number of pressure and cycle sensor inputs: | 3 |
Number of pump elements: | Up to 3 |
Number of sensor inputs: | 3, 1 |
Permissible operating pressure (bar): | 351.6 |
Power connection type: | DIN |
Relief valve, output voltage (VDC): | 24 |
Relief valve maximum operating current (A): | 2 |
Relief valve maximum operating power (W): | 48 |
Required input switch type: | Normally open |
Reservoir size (L): | 2 |
Resistive maximum operating current, alarm relay (A): | 3 |
Resistive maximum permissible load, alarm relay: | 10µA;10m VDC |
Resistive maximum rated load, alarm relay (A): | 2 |
Resistive maximum switching capacity, alarm relay: | 50VA;60W |
Sensor input voltage (VDC): | 24 |
Series: | Max |
Size of the material outlet opening (inches): | 0.25 |
Switching current (A), low level: | 0.5 |
Total depth (cm): | 9/22 |
Total depth (mm): | 229 |
Total height (cm): | 33.7 |
Total height (mm): | 337 |
Total width (cm): | 20.3 |
Total width (mm): | 203 |
Type: | Electric piston pump |
Voltage (V): | 24VDC |
Voltage (V dc): | 24 |
Weight (kg): | 6 |
Wetted material: | Nylon, Trogamid T5004-060, Galvanized Steel, Mild Steel, Alloy Steel, Stainless Steel, Nitrile Rubber, Bronze, Nickel Plated Alnico, Chemically Lubricated Acetal, Aluminum, PTFE, Grillamid |
- Product number: 1037324
- Manufacturer: Graco
- EAN: 00633955558816
- Weight: 7.475 kg
- Length: 310 mm
- Width: 310 mm
- Height: 390 mm
Technical details
Operating specifications
UPC product | 6 3 3955558816 |
---|---|
Division | LED |
Price Block | 128 |
Country of origin | US |
Unit | EA |
Height | 39 CM |
Length | 31 cm |
Width | 31 cm |
Volume | . 037 m³ |
Shipping weight | 7 .48 KG |
Technical
Fluid outlet size (mm) | 6. 3500 |
---|---|
Fluid outlet thread gender | Female |
For use with | Injector-based systems, series progressive systems |
Includes | Machine Count, Vent Valve, DIN Alarm Output, M12 Connection for Remote, Follower Plate, Low Level |
Maximum NLGI grade | #2 |
Maximum working pressure (bar) | 351. 6 |
Maximum working pressure (kPa) | 3 5160 |
Maximum working pressure (psi) | 5 1 00 |
Model | G3 |
Reservoir Size (gal) | 0. 528 |
Series | Max |
Voltage (V DC) | 2 4 |
Alarm relay inductive maximum operating voltage (VDC) | 220 |
Alarm relay inductive maximum switching capacity | 25 VA; 30 W |
Alarm relay inductive minimum permissible load | 10 ?A;10m VDC |
Alarm relay inductive rated load (A) | 1 |
Alarm relay resistive maximum operating current (A) | 3 |
Alarm relay resistive maximum switching capacity | 50 VA; 60 W |
Alarm relay resistive minimum permissible load | 10 µA; 10m VDC |
Alarm relay resistive rated load (A) | 2 |
Control options | Max |
Input Cycle Rate (Hz) | 8 |
Input Impedance | 1. 1 |
Input load current (mA @ 24 VDC) | 2 2 |
Input Maximum Off Current (mA) | 1. 5 |
Input Maximum Residual Voltage (V) | 4 |
Input required switch type | Normally Open |
Input sensor voltage (VDC) | 2 4 |
IP Rating | IP 6 9K |
Low Level Carry Current (A) | 1. 2 |
Low Level Contact Rating (W) | 10 |
Low Level Switch Rating (VDC) | 2 00 |
Low level switching current (A) | 0. 5 |
Maximum fill inlet pressure (bar) | 344. 7 |
Maximum fill inlet pressure (kPa) | 3 4 470 |
Maximum fill inlet pressure (psi) | 5 0 00 |
Maximum run time (min) | 30 |
Maximum voltage (V DC) | 32 |
Minimum voltage (V DC) | 18 |
Number of machine count sensor inputs | 1 |
Number of pressure and cycle sensor inputs | 3 |
Number of pump elements | Up to 3 |
Number of sensor inputs | 3, 1 |
Overall depth (cm) | 22. 9 |
Overall depth (in) | 9 |
Overall Depth (mm) | 229 |
Overall height (cm) | 33. 7 |
Overall height (in) | 13. 25 |
Overall height (mm) | 337 |
Overall Width (cm) | 20. 3 |
Overall width (in) | 8 |
Overall width (mm) | 203 |
Pump Output with 0 Spacers (cu in/min) | 0. 25 |
Pump output with 1 spacer (cu in/min) | 0. 18 |
Pump output with 2 spacers (cu in/min) | 0. 12 |
Vent valve maximum operating current (A) | 2 |
Vent valve maximum operating power (W) | 48 |
Vent valve output voltage (VDC) | 2 4 |
Weight (kg) | 6 |
Maximum working pressure (MPa) | 35. 1 |
cellular connectivity | No |
Register